BATTERY | |||||
Battery Module numbers | 1 | 2 | 3 | 4 | |
Battery Energy | 5.12kWh | 10.24kWh | 15.36kWh | 20.48kWh | |
Battery Capacity | 100AH | 200AH | 300AH | 400AH | |
Weight | 80kg | 133kg | 186kg | 239kg | |
Dimension L× D× H | 600×300×540 | 600×300×840 | 600×300×1240 | 600×300×1540 | |
Battery Type | LiFePO4 | ||||
Battery Rated Voltage | 51.2V | ||||
Battery Working Voltage Range | 40.0V ~ 58.4V | ||||
Maximum Charging Current | 100A | ||||
Maximum Discharging Current | 100A | ||||
DOD | 80% | ||||
Parallel Quantity | 4 | ||||
Designed Life-span | 6000Cycles | ||||
Inver & Controller | |||||
Rated Power | 5000W | ||||
Peak Power(20ms) | 15KVA | ||||
PV (Not include PV) | Charging Mode | MPPT | |||
| Rated PV input voltage | 360VDC | |||
| MPPT tracking voltage range | 120V-450V | |||
| Max PV Input Voltage Voc (At the lowest temperature) | 500V | |||
| PV Array Maximum Power | 6000W | |||
| MPPT tracking channels (input channels) | 1 | |||
Input | DC Input Voltage Range | 42VDC-60VDC | |||
| Rated AC input voltage | 220VAC / 230VAC / 240VAC | |||
| AC Input Voltage Range | 170VAC~280VAC (UPS mode)/ 120VAC~280VAC(INV mode) | |||
| AC Input Frequency Range | 45Hz~55Hz(50Hz),55Hz~65Hz(60Hz) | |||
Output | Output efficiency(Battery/PV Mode) | 94%(Peak value) | |||
| Output Voltage(Battery/PV Mode) | 220VAC±2% / 230VAC±2% / 240VAC±2% | |||
| Output Frequency(Battery/PV Mode) | 50Hz±0.5 or 60Hz±0.5 | |||
| Output Wave(Battery/PV Mode) | Pure Sine Wave | |||
| Efficiency(AC Mode) | >99% | |||
| Output Voltage(AC Mode) | Follow input | |||
| Output Frequency(AC Mode) | Follow input | |||
| Output waveform distortion Battery/PV Mode) | ≤3%(Linear load) | |||
| No load loss(Battery Mode) | ≤1% rated power | |||
| No load loss(AC Mode) | ≤0.5% rated power(charger does not work in AC mode) | |||
Protection | Battery low voltage alarm | Battery undervoltage protection value+0.5V(Single battery voltage) | |||
| Battery low voltage protection | Factory default: 10.5V(Single battery voltage) | |||
| Battery over voltage alarm | Constant charge voltage+0.8V(Single battery voltage) | |||
| Battery over voltage protection | Factory default: 17V(Single battery voltage) | |||
| Battery over voltage recovery voltage | Battery overvoltage protection value-1V(Single battery voltage) | |||
| Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |||
| Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |||
| Temperature protection | >90°C(Shut down output) | |||
Working Mode | Mains priority/Solar priority/Battery priority(Can be set) | ||||
Transfer Time | ≤10ms | ||||
Display | LCD+LED | ||||
Thermal method | Cooling fan in intelligent control | ||||
Communication(Optional) | RS485/APP(WIFI monitoring or GPRS monitoring) | ||||
Environment | Operating temperature | -10℃~40℃ | |||
| Storage temperature | -15℃~60℃ | |||
| Noise | ≤55dB | |||
| Elevation | 2000m(More than derating) | |||
| Humidity | 0%~95% (No condensation) |